Give your pyranometers the protection they deserve! SPD01 is a surge protection device for digital pyranometers. The SPD01 reduces the risk of costly instrument damage and data loss for connected devices, by serving as an additional layer of external protection against high-impulse currents and voltages - surges. For example, seasonal lightning and inductive switching are common sources of surges in PV power plants.

Would you like a personalised quote?

or contact us: info@hukseflux.com

Specifications

Surge immunity*
  • :
Surge Immunity (EN-IEC 61000-4-5:2014)
  • Level 4
Maximum line-to-line surge**
  • 2 kV, 1 kA
Maximum line-to-ground surge**
  • 4 kV, 2 KA
Number of protected instruments
  • up to 3
Data lines
  • :
Common mode signal voltage range
  • ± 12 V
Differential mode signal voltage range
  • ± 12 V
Maximum line-to-earth voltage
  • 12 V
Mechanical
  • :
Housing material
  • ASA/PC UL94 V0-1.5mm
Cable glands
  • M12 (protected)
Cable diameter
  • (3 to 6) mm
Optional SMF01: rated pole mount diameter
  • (40 to 60) mm
Weight
  • 0.7 kg
DC power lines
  • :
Rated operating DC input voltage range
  • ± 30 V
Maximum DC input current
  • 5 A
Total DC output current
  • 5 A
Rated operating conditions
  • :
Required over-current protection
  • ≤ 5 A slow blow fuse
Rated operating temperature range
  • (-40 to +80) °C
*
  • tested with all Hukseflux Industrial pyranometers
**
  • all lines tested as DC power lines
Options
  • SMF01 SPD mounting fixture (tube mounting fixture with 2 x 40-60 mm tube clamp)
  • PID01 Pyranometer Isolation Disc
Downloads
SPD01 brochure

Description

SPD01 Surge Protection Device

Immunity to high voltages and currents - surges

SPD01 is a surge protection device for digital pyranometers. It is designed for use with the Hukseflux-brand “industrial pyranometer” series of instruments. The device combines and coordinates the protection of the power supply and the RS-485 serial communication lines. Protection of the pyranometer against electrical surges is very important to guarantee reliable operation in harsh “industry grade” outdoor environments such as solar (PV) power plants and meteorological stations. Hukseflux industrial pyranometers are tested and classified for Industrial Environments according to IEC 61326-1 and IEC 61000-6-2.

Protection against surges on PV park

Why add an SPD?

When designing a measurement system, pyranometer users may attain several levels of immunity. For example, the surge immunity of the SR300-D1 industrial pyranometer is Level 2 (up to 1 kV surges) according to IEC 61000-4-5. Adding the Surge Protection Device SPD01, the immunity is increased to 4 kV.

To attain the required level of immunity for a given installation, some general system components should be included, such as:

•    lightning protection system
•    earthing and grounding network
•    external surge protection in addition to the native on-board sensor protection 

SPD01 Surge Protection Device

SPD01 properties

In the electrically harsh environment of PV power plants, SPD01 protects connected instruments from lightning - and power-switching induced surge events. At the same time, it allows for a flexible system design. Properly installing the SPD01 near a Hukseflux industrial pyranometer, assures that voltages and currents reaching the sensor are strongly suppressed. 

SPD01 Surge Protection Device

System design

Provided that instruments are in close proximity to the SPD, up to 3 instruments can be protected by a single SPD01. 

  • instruments are protected from surges in the grounding system
  • the distance between the instrument and SCADA system may be increased significantly

Depending on the system design and instrument location, multiple SPD01’s may be used. 

In some cases, for example on-array installation of pyranometers, it is beneficial to isolate the instruments from the mounting platform. Hukseflux supplies an optional accessory for this, the PID01 Pyranometer Isolation Disc.

SMF01

Optional SMF01

SMF01 is a practical metal bracket that helps mounting a surge protection device on a vertical mast. 

Suggested use

  • PV system performance monitoring
  • scientific meteorological observations

Frequently asked questions

How does a pyranometer work?

A pyranometer measures the solar radiation received by a plane surface from a 180 ° field of view angle. This quantity, expressed in W/m², is called “hemispherical” solar radiation. The solar radiation spectrum extends roughly from 285 to 3000 x 10⁻⁹ m. By definition a pyranometer should cover that spectral range with a spectral selectivity that is as “flat” as possible.

In an irradiance measurement by definition the response to “beam” radiation varies with the cosine of the angle of incidence; i.e. it should have full response when the solar radiation hits the sensor perpendicularly (normal to the surface, sun at zenith, 0 ° angle of incidence), zero response when the sun is at the horizon (90 ° angle of incidence, 90 ° zenith angle), and 50 % of full response at 60 ° angle of incidence. A pyranometer should have a so-called “directional response” (older documents mention “cosine response”) that is as close as possible to the ideal cosine characteristic.

In order to attain the proper directional and spectral characteristics, a pyranometer's main components are:

•    a thermal sensor with black coating. It has a flat spectrum covering the 200 to 50000 x 10⁻⁹ m range, and has a near-perfect directional response. The coating absorbs all solar radiation and, at the moment of absorption, converts it to heat. The heat flows through the sensor to the sensor body. The thermopile sensor generates a voltage output signal that is proportional to the solar irradiance.

•    a glass dome. This dome limits the spectral range from 285 to 3000 x 10⁻⁹ m (cutting off the part above 3000 x 10⁻⁹ m), while preserving the 180 ° field of view angle. Another function of the dome is that it shields the thermopile sensor from the environment (convection, rain).

•    a second (inner) glass dome: For secondary standard and first class pyranometers, two domes are used, and not one single dome. This construction provides an additional "radiation shield", resulting in a better thermal equilibrium between the sensor and inner dome, compared to using a single dome. The effect of having a second dome is a strong reduction of instrument offsets.

•    a heater: in order to reduce the effect of dew deposition and frost on the outer dome surface, most advanced pyranometers have a built-in heater. The heater is coupled to the sensor body. Heating a pyranometer can generate additional irradiance offset signals, therefore it is recommended to activate the heater only during night-time. Combining a heater with external ventilation makes these heating offsets very low.

Why use a pyranometer?

There are good reasons why pyranometers are the standard for solar radiation measurement in outdoor PV system performance monitoring. 

The purpose of outdoor PV testing is to compare the available resource to system output and thus to determine efficiency. The efficiency estimate serves as an indication of overall performance and stability. It also serves as a reference for remote diagnostics and need for servicing.

The irradiance measurement for outdoor PV performance monitoring is usually carried out with pyranometers. Some standards suggest using PV reference cells. Reference cells are (with some minor exceptions) unsuitable for proof in bankability and in proof of PV system efficiency. Pyranometers are and will remain the standard for outdoor solar energy monitoring.

From a fundamental point of view:

  • Pyranometers measure truly available solar irradiance (so the amount of available resource). This is the parameter you need to have for a true efficiency calculation.
  • Reference cells measure only that part of solar radiation that can be used by cells of identical material and identical packaging (flat window), so the yield of a certain PV cell type. This is not a measurement that can be used in an efficiency calculation and in fact leads to several percentage points error in efficiency estimates.

The International Energy Agency (IEA) and ASTM standards for PV monitoring recommend pyranometers for outdoor PV monitoring. PV reference cells do not meet IEC 61724-1 class A requirements for irradiance measurement uncertainty: their directional response makes them systematically overestimate daily radiant exposure in J/m2 (or W·hr/m2 ) by more than 2 %, larger on hourly basis. 

How do I choose a pyranometer?

Choosing the right pyranometer for your application is not an easy task. We can offer assistance. But first, you should ask yourself the following questions:

  • are there standards for my application?
  • what level of accuracy do I need?
  • what will be the instrument maintenance level?
  • what are the interfacing possibilities?

When discussing with Hukseflux, our recommendation for the best suited pyranometer will be based on:

  • recommended pyranometer class
  • recommended maintenance level
  • estimate of the measurement accuracy
  • recommended calibration policy
  • recommended interface

Pyranometers can be manufactured to different specifications and with different levels of verification and characterisation during production. The ISO 9060 - 1990 standard, “Solar energy - specification and classification of instruments for measuring hemispherical solar and direct solar radiation”, distinguishes between 3 classes; secondary standard (highest accuracy), first class (second highest accuracy) and second class (third highest accuracy). From second class to first class and from first class to secondary standard, the achievable accuracy improves by a factor 2.

The ISO 9060 - 1990 standard is up for revision. The new 2018 version of the standard will be slightly different from the 1990 version. The new version of ISO 9060 includes three instrument accuracy classes A, B and C, and a special extension of every class “Spectrally Flat”, which is recommended for Plane of Array (POA), albedo, and reflected solar measurements.

Our pyranometer selection guide offers practical guidelines for choosing a pyranometer. The application of pyranometers in PV system performance monitoring according to IEC 61724-1 is highlighted as an example. Sensors specific for diffuse radiation and meteorological networks are also addressed in this selection guide.

What is the difference between a pyrheliometer and a pyranometer?

A pyranometer measures hemispherical solar radiation. When measuring in the horizontal plane this is called Global Horizontal Irradiance (GHI). When measuring in “plane of array”, next to PV panels, this is called plane of array POA irradiance.

A pyrheliometer is used to measure Direct Normal Irradiance (DNI). DNI is defined as the solar radiant flux collected by a plane unit surface normal to the axis pointing towards the centre of the sun, within an optical angular aperture. DNI is composed of the solar irradiance within the extent of the solar disk (half-angle 0.266 ° ± 1.7 %) plus some circumsolar radiation.

SPD01 Surge Protection Device
SPD01 Surge Protection Device
  • Protection against high-impulse currents and voltages - surges
  • Protects up to 3 connected digital pyranometers
  • Up to 4 kV surge protection (IEC 61000-4-5 Level 4)
  • Passive device: no power required for protective functionality
  • Rugged, weatherproof (IP66) housing
  • Designed for Hukseflux-brand “industrial pyranometer” series