BLK - GLD sticker series

BLK - GLD sticker series, accessory for FHF05, FHF04, FHF04SC, FHF03 and HFP01 heat flux sensors
BLK – GLD sticker series for heat flux measurement
BLK – GLD sticker series for heat flux measurement
BLK – GLD sticker series for heat flux measurement
External video URL
How to install black and gold stickers (on a heat flux sensor)

Black and gold stickers for measuring convective and radiative heat flux separately

Want to study energy transport / heat flux in detail? Hukseflux helps taking your measurement to the next level. Simply provide your heat flux sensors with radiation-absorbing black and radiation-reflecting gold stickers. You can then measure convective + radiative flux with one, and only convective flux with the other. Subtract the two measurements and you have radiative flux. BLK and GLD stickers are available for sensor models FHF05 series and HFP01. They are designed to be applied by the user to the sensor; see the user manual and installation video for instructions.

Specifications

Measurand
  • convective and / or radiative heat flux
Would you like a personalised quote?

or contact us: info@hukseflux.com

Specifications

Measurand
  • convective and / or radiative heat flux
BLK
  • :
Measurand
  • convective and radiative heat flux
Spectral range (UV-VIS-NIR-FIR)
  • 250 to > 10000 x 10⁻⁹ m
Absorption over range
  • > 95 %
Rated temperature range - continuous use
  • -40 to +150 °C*
Rated temperature range - short intervals
  • -40 to +260 °C*
GLD
  • :
Measurand
  • convective heat flux
Spectral range (NIR-FIR)
  • 700 to > 10000 x 10⁻⁹ m
Reflection over range
  • > 95 %
Spectral range (VIS)
  • 400 to 700 x 10⁻⁹ m
Reflection over range
  • > 80 %
Solar absorption
  • < 20 %
Rated temperature range - continuous use
  • -185 to +150 °C*
Rated temperature range - short intervals
  • -185 to +260 °C*
Working with BLK – GLD sticker series
  • :
Effect on sensor sensitivity
  • negligible
Application on sensor
  • by user or at factory see user manual and instruction video
Versions and order codes
  • :
GLD for use with FHF05(SC)
  • GLD-10X10, GLD-15X30, GLD-50X50 (SC), GLD-15X85, GLD-85X85 (SC)
BLK for use with FHF05(SC):
  • BLK-10X10, BLK-15X30, BLK-50X50 (SC), BLK-15X85, BLK-85X85 (SC)
GLD for use with HFP01:
  • GLD-80
BLK for use with HFP01:
  • BLK-80
*
  • See also the rated temperature ranges in the sensor user manuals
Options

pre-applied to the sensor at the factory

Description

BLK – GLD sticker series allows users, measuring heat flux, to measure only radiative or only convective heat flux.

Heat flux measurement is a powerful tool to gain insights into processes involving thermal energy. Heat flux consists of conductive, convective and radiative flux. Measuring heat flux, users may wish to measure only radiative or only convective heat flux. This is now possible with the BLK – GLD sticker series, designed to be used with a wide range of our market-leading heat flux sensors. The BLK black absorbing stickers will absorb all radiation and are sensitive to both radiative and convective heat flux, while the GLD gold reflective stickers reflect all radiation and are sensitive to convective heat flux only. Combining BLK and GLD, applied to two separate heat flux sensors, will allow for measuring radiative heat flux:

Φ radiation + convection = Φ BLK

Φ convection = Φ GLD

Φ radiation = Φ BLK - Φ GLD

Black and Gold stickers for heat flux measurement

BLK – GLD sticker series has unique features and benefits:

  • makes it possible to perform convective and radiative heat flux measurements
  • available as accessory for FHF05(SC) series and HFP01 heat flux sensors
  • designed to be applied by the user (See also the instruction video on our YouTube channel)

 

Stickers available for FHF05 and HFP01 heat flux meters

BLK – GLD stickers are designed to be applied by the user, but can optionally also be pre-applied at the factory. Applying a sticker to a heat flux sensor does not change the sensitivity of the sensor, so no additional calibration is required. Using the reliable measurement technology behind our heat flux sensors, separating convective and radiative heat flux has never been easier.

radiation-absorbing black and radiation-reflecting gold stickers for use with a range of sensors

The working principle of BLK – GLD stickers: sensors equipped with black absorbing stickers will absorb all radiation while gold reflective stickers reflect all radiation. Both stickers are sensitive to convective heat flux. The image shows FHF05 heat flux sensor with BLK-50X50 black and GLD-50X50 gold sticker.

BLK - GLD sticker series application procedure instruction movie
External video URL

Suggested use

Measuring heat flux, users may wish to measure only radiative or only convective heat flux. This is now possible with the BLK – GLD sticker series, designed to be used with a wide range of our market-leading heat flux sensors. BLK – GLD stickers are designed to be applied by the user, but can optionally also be pre-applied at the factory. See also the application procedure instruction video on our YouTube channel.

BLK - GLD sticker series
BLK - GLD sticker series, accessory for FHF05, FHF04, FHF04SC, FHF03 and HFP01 heat flux sensors

 

  • makes it possible to perform convective and radiative heat flux measurements
  • available as accessory for FHF05(SC) series and HFP01 heat flux sensors
  • designed to be applied by the user
Would you like a personalised quote?

or contact us: info@hukseflux.com